Can't find it? Call us toll free... 888-454-4480 M-F 7am-6pm Central

Checkout

Industrial and commercial lighting at wholesale prices

Live Chat LIVE CHAT
Call us toll free...888-454-4480

Hazardous Area / Explosion Proof Lighting


Hazardous Area / Explosion Proof Lighting from Warehouse Lighting delivers superior illumination in the most extreme environments. A hazardous location is defined as a place where concentrations of flammable gases, vapors or dusts occur. Electrical equipment that must be installed in such locations is specially designed and tested to ensure it does not initiate an explosion, due to arcing contacts or high surface temperature of the equipment. Scroll down to the bottom of the page to see detailed descriptions of all divisions, zones and classifications of hazardous areas.

Proper lighting is extremely important for a variety of reasons. It helps you perform work and complete tasks by ensuring you can always see what you are doing. It keeps you aware of your environment and improves safety. Best of all, it provides a more comfortable atmosphere that will help you feel less stressed. Light fixtures are an electrical appliance, however, and can be dangerous in some locations. Stray sparks can set off a buildup of flammable gasses and materials, which is why having explosion proof lighting is important. We have several fixtures that will give you great lighting while also allowing you to take your mind off your hardware. Our lighting solutions use powerful LED technology to help create widespread illumination while minimizing risk. LEDs are more efficient and more powerful, with great performance that will also lower your power bill. Also, their durable construction ensures they are perfectly safe in any environment. Not only do these options provide less hazard themselves, they can be contained in very durable housing that ensures they are protected from the gas, debris, and other elements of the environment while the environment is also protected from them.

Each of these explosion proof lighting fixtures is classified by which areas it is best suited for. Check out our zoning information at the bottom of the page to make sure you get the right match for the area you intended to work in. This will ensure you get light fixtures with the reliability you need.


Show    Products 1-14 of 14
4 Foot, 2 Lamp Explosion Proof LED Paint Spray Booth Light, 56W
  • Brand: Larson Electronics
  • Wattage: 56 (28 watts per lamp)
  • Voltage: 120-277
  • Class I Division 1, Groups C and D
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 1 & 2, Groups E, F and G
  • Life: 50,000+ hours
  • CCT: 5600K
  • CRI: >80
  • Lumens: 7,000 (3,500 per lamp)
  • Beam Angle: 150°
  • 5 year warranty
  • See spec sheet for more info
EPL-48-2L-LED-SFC-1227-5600K

Price: Call For Pricing

American Made UL Listed 5 Year Warranty
4 Foot, 2 Lamp Hazardous Area Offshore LED Light for Corrosive Marine Environments, 56W
  • Brand: Larson Electronics
  • Wattage: 56 (28 watts per lamp)
  • Voltage: 120-277
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 2, Groups F, G
  • Life: 50,000+ hours
  • CCT: 5600K
  • CRI: 90
  • Lumens: 7,000 (3,500 per lamp)
  • Beam Angle: 150°
  • 3 year warranty
  • See spec sheet for more info
HALP-48-2L-LED-SFC-1227-5600K

Price: Call For Pricing

American Made UL Listed 3 Year Warranty
4 Foot, 2 Lamp Hazardous Area Offshore LED Rig Light, 56W
  • Brand: Larson Electronics
  • Wattage: 56 (28 watts per lamp)
  • Voltage: 120-277
  • Class I, Division 2, Groups A, B, C and D
  • Life: 50,000+ hours
  • CCT: 5600K
  • CRI: 75
  • Lumens: 7,000 (3,500 per lamp)
  • Beam Angle: 150°
  • 5 year warranty
  • See spec sheet for more info
HAL-48-2L-LED-BMSW-1227-5600K

Price: Call For Pricing

American Made UL Listed 5 Year Warranty
4 Foot, 2 Lamp Stainless Steel Hazardous Area Offshore LED Light for Corrosive Marine Environments, 56W
  • Brand: Larson Electronics
  • Wattage: 56 (28 watts per lamp)
  • Voltage: 120-277
  • Class 1 Division 2, Groups A, B, C, D
  • Life: 50,000+ hours
  • CCT: 5600K
  • CRI: 90
  • Lumens: 6,720
  • Beam Angle: 150°
  • 3 year warranty
  • See spec sheet for more info
HALSS-48-2L-LED-1227VAC

Price: Call For Pricing

American Made UL Listed 3 Year Warranty
4 Foot, 4 Lamp Explosion Proof LED Paint Spray Booth Light, 112W
  • Brand: Larson Electronics
  • Wattage: 112 (28 watts per lamp)
  • Voltage: 120-277
  • Class I Division 1, Groups C and D T6
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 1 & 2, Groups E, F and G
  • Life: 50,000+ hours
  • CCT: 5600K
  • CRI: >80
  • Lumens: 14,000 (3,500 per lamp)
  • Beam Angle: 150°
  • 5 year warranty
  • See spec sheet for more info
EPL-48-4L-LED-VAC-5600K-SFC

Price: Call For Pricing

American Made UL Listed 5 Year Warranty
Explosion Proof LED High Bay, 150W
  • Brand: Larson Electronics
  • Wattage: 150
  • Voltage: 100-277
  • Class I, Divisions 1 & 2, Groups C and D
  • Class II, Divisions 1 & 2, Groups E,F,G
  • Class III, Divisions 1 & 2
  • Life: 60,000+ hours
  • CCT: 5600K
  • CRI: >75
  • Lumens: 13,000
  • Beam Angle: 60° or 125°
  • 5 year warranty
  • See spec sheet for more info
EPL-HB-150LED-RT-1227-60B-56K

Price: Call For Pricing

UL Listed 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.04
  • Brand: Noribachi
  • UL 844
  • Choice of:
    • 24 LEDs-24 watt-3,360 lumens
    • 24 LEDs- 36 watt-5,040 lumens
    • 24 LEDs-17 watt-1,488 lumens - Red
    • 24 LEDs-24 watt-2,232 lumens - Red
    • 24 LEDs-25 watt-2,736 lumens - Green
    • 24 LEDs-36 watt-1,432 lumens - Green
    • 24 LEDs-25 watt-1,097 lumens - Blue
    • 24 LEDs-36 watt-1,645 lumens - Blue
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-04

Price: $856.67

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.02
  • Brand: Noribachi
  • Class 1, Division 2
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-02

Price: $1,070.00

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.07
  • Brand: Noribachi
  • Class 1, Division 2, Groups A, B, C, D
  • UL 844 & 595
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
    • 105 LEDs-158 watt-22,120 lumens
    • 126 LEDs-189 watt-26,460 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-07

Price: $1,418.33

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.08
  • Brand: Noribachi
  • Class 1, Division 2, Groups A, B, C, D
  • Class 2, Division 2, Group F & G
  • UL 844
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
    • 105 LEDs-158 watt-22,120 lumens
    • 126 LEDs-189 watt-26,460 lumens
    • 168 LEDs-252 watt-35,280 lumens
    • 210 LEDs-315 watt-44,100 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-08

Price: $1,938.33

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.05
  • Brand: Noribachi
  • Class 1, Division 2, Groups A, B, C, D
  • UL 844 & 595
  • Meets Coast Guard Specifications
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
    • 105 LEDs-158 watt-22,120 lumens
    • 126 LEDs-189 watt-26,460 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-05

Price: $2,540.00

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.01
  • Brand: Noribachi
  • Explosion Proof Fixture
  • Class 1, Division 1
  • UL 844
  • UL 1598
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-01

Price: $2,665.00

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.03
  • Brand: Noribachi
  • Class 1, Division 2, Groups A, B, C, D
  • Class 1, Zone 2, AEx nR, Groups IIA, IIB, IIC
  • UL Standard 1598, 1598A & 844
  • Choice of:
    • 21 LEDs-32 watt-4,480 lumens
    • 42 LEDs-63 watt-8,820 lumens
    • 63 LEDs-95 watt-13,300 lumens
    • 84 LEDs-126 watt-17,640 lumens
    • 105 LEDs-158 watt-22,120 lumens
    • 126 LEDs-189 watt-26,460 lumens
    • 140 LEDs-210 watt-29,400 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-03

Price: $3,140.00

American Made ETL 5 Year Warranty
Noribachi Hazardous Area LED Fixture - NHS.06
  • Brand: Noribachi
  • Explosion Proof Fixture
  • Class 1, Division 1, Group C & D
  • Class 2, Division 1 & 2, Group E, F, G
  • UL 844, 924 & 1598A
  • 96 LEDs-144 watt-20,300 lumens
  • Voltage: 120-277
  • Power Factor: >.9
  • Min. CRI: 70
  • L70 Life: 100,000+ hrs
  • Operating Temp: -40C to +65C
  • 5 Year Warranty
  • See spec sheet and call for more options.
NHS-06

Price: $3,578.33

American Made ETL 5 Year Warranty

Gas Divisions or Zones

Non-Hazardous Area

An area such as a residence or office would be classed as Non Hazardous (safe area), where the only risk of a release of explosive or flammable gas would be such things as the propellant in an aerosol spray. The only explosive or flammable liquid would be paint and brush cleaner. These are classed as very low risk of causing an explosion and are more of a fire risk (although gas explosions in residential buildings do occur). Non hazardous areas on chemical and other plant are present where it is absolutely certain that the hazardous gas is diluted to a concentration below 25% of its lower flammability limit (or lower explosive limit).

Division 2 or Zone 2 Area

This is a step up from the safe area. In this zone the gas, vapor or mist would only be present under abnormal conditions (most often leaks under abnormal conditions). As a general guide for Zone 2, unwanted substances should only be present under 10 hours/year or 0–0.1% of the time.

Division 1 or Zone 1 Area

Gas, vapor or mist will be present or expected to be present for long periods of time under normal operating conditions. As a guide for Zone 1, this can be defined as 10–1000 hours/year or 0.1–10% of the time.

Zone 0 Area

Gas or vapor is present all of the time. An example of this would be the vapor space above the liquid in the top of a tank or drum. The ANSI/NEC classification method consider this environment a Division 1 area. As a guide for Zone 0, this can be defined as over 1000 hours/year or >10% of the time.

Dust Zones

Zone 22

A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Zone 21

A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is likely to occur, occasionally, in normal operation.

Zone 20

A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is present continuously, or for long periods or frequently.

ANSI/NFPA/NEC Areas Description

Class 1, Div. 1 - Where ignitable concentrations of flammable gases, vapors or liquids are present continuously or frequently within the atmosphere under normal operation conditions.

Class 1, Div. 2 - Where ignitable concentrations of flammable gases, vapors, or liquids are present within the atmosphere under abnormal operating conditions.

Class 2, Div. 1 - Where ignitable concentrations of combustible dusts are present within the atmosphere under normal operation conditions.

Class 2, Div. 2 - Where ignitable concentrations of combustible dust are present within the atmosphere under abnormal operating conditions.

Class 3, Div. 1 - Where easily ignitable fibers or materials producing combustible flyings are present within the atmosphere under normal operation conditions.

Class 3, Div. 2 - Where easily ignitable fibers or materials producing combustible flyings are present within the atmosphere under abnormal operating conditions.

Class 1 Areas: Group A: Acetylene / Group B: Hydrogen / Group C: Propane and Ethylene / Group D: Benzene, Butane, Methane & Propane

Class 2 Areas: Group E: Metal Dust / Group F: Carbon & Charcoal / Group G: Flour, Starch, Wood & Plastic

Class 3 Areas: NO GROUP: Cotton & Sawdust

© 2016 Warehouse-Lighting.com