6-inch Vertical Lamp Compact Fluorescent, Type IC, New Construction Housing for (1) CFL double- or triple tube 26W lamp (Lamps not included)

SKU WL-109882
  • Usually ShipsNext Day
Our Price   $31.73 On Sale Today!
Qty  
 

Volume Discounts

QtyPrice
10$31.73
20$30.75
40$29.77
70$28.78

NOTE: Volume Discounts will not reflect Sale prices until you add this product to your cart.

Specifications

Features: Lamps are NOT included AIRTIGHT - meets IECC Energy Code. (Less than 2 CFM leakage at 1.57 PSI) Performance tested per ASTM E283-84 Ceiling Cut-Out: 6-3/8 in. Plaster Frame: 7-5/8 in.W x 12-1/2 in.L Lamp: One 26W Lamp Base: 4-pin G24q-3 or GX24q-3 Minimum Starting Temperature: -18 degree C (0 degree F) 120V electronic NPF ballast UL, cUL listed for use in damp locations (wet location trims available) Thermally protected, fused, 120v electronic ballast with end-of-lamp-life protection J-box is listed for eight (4in - 4out) No. 12AWG (90 degrees C) through-branch circuit conductors and has five 1/2 in., one 3/4 in. and four Romex knockouts with true pry out slots Romex knockouts include built in strain relief - no additional clamps required Pre-installed hanger bars allow housing to be positioned at any point within 24 in. joist span. Score lines provided for easy field shortening to accommodate 12 in. joist span Hanger bars can easily be field repositioned 90 degrees on the plaster frame Hanger bars are designed to fit on to T-Bar spine for quick alignment and can be permanently secured without the need for additional clips Meets stringent energy star requirements, including FCC title 47 CFR part 18 for consumer equipment Housing adjusts for ceilings up to 1-3/8 in. thick 7-1/2 in. housing height allows use in 2 in. x 8 in. joist construction Sealed and gasketed construction limits air exchange between the ceiling plenum and heated or air conditioned areas - performance tested to ASTM-E283 (Washington State) Meets State of California Title 24 requirements 2-year warranty
  • AIRTIGHT - meets IECC Energy Code. (Less than 2 CFM leakage at 1.57 PSI) Performance tested per ASTM E283-84
  • Ceiling Cut-Out: 6-3/8 in.
  • Plaster Frame: 7-5/8 in.W x 12-1/2 in.L
  • Lamp: One 26W
  • Lamp Base: 4-pin G24q-3 or GX24q-3
  • Minimum Starting Temperature: -18 degree C (0 degree F)
  • 120V electronic NPF ballast
  • UL, cUL listed for use in damp locations (wet location trims available)
  • Thermally protected, fused, 120v electronic ballast with end-of-lamp-life protection
  • J-box is listed for eight (4in - 4out) No. 12AWG (90 degrees C) through-branch circuit conductors and has five 1/2 in., one 3/4 in. and four Romex knockouts with true pry out slots
  • Romex knockouts include built in strain relief - no additional clamps required
  • Pre-installed hanger bars allow housing to be positioned at any point within 24 in. joist span. Score lines provided for easy field shortening to accommodate 12 in. joist span
  • Hanger bars can easily be field repositioned 90 degrees on the plaster frame
  • Hanger bars are designed to fit on to T-Bar spine for quick alignment and can be permanently secured without the need for additional clips
  • Meets stringent energy star requirements, including FCC title 47 CFR part 18 for consumer equipment
  • Housing adjusts for ceilings up to 1-3/8 in. thick
  • 7-1/2 in. housi